- by Ph.D Karin Hsiao
Healing Pod Protocol: Complete Guide to Safe & Effective Red Light Therapy
- by Ph.D Karin Hsiao
Review and fully understand all safety information and manufacturer instructions before use.
Obtain medical clearance if any contraindications are present, including—but not limited to—active skin disease, implanted medical or metallic devices, seizure disorders, pregnancy, or known photosensitivity.
Place the device on a stable, flat, and dry surface.
Connect the controller securely to the pod, then plug the power adapter into a grounded wall outlet.
Maintain appropriate hydration before and after each session.

Session length: 5–30 minutes, based on comfort and therapeutic objectives.
Recommended frequency: 3–4 sessions per week for optimal cumulative benefit.
Intensity (Power level): Begin at P2–P3, increasing gradually only if well-tolerated.
Mode selection:
Continuous (non-pulsed): General wellness, circulation, soft-tissue support
10 Hz pulsed: Relaxation and autonomic nervous system regulation
40 Hz pulsed: Cognitive stimulation and mental clarity
Use the controller’s integrated timer to set treatment duration; the system will automatically shut off when completed.
If excessive warmth, discomfort, dizziness, or irritation occurs, reduce intensity or discontinue treatment immediately using the power button.
Keep eyes closed during operation and avoid direct exposure to LEDs.

| Category | Mode | Time | Intensity | Clinical Benefit |
|---|---|---|---|---|
| Relaxation | 10 Hz | 15–25 min | P2–P3 | Supports nervous system calming |
| Cognitive Clarity | 40 Hz | 10–20 min | P2–P3 | Enhances focus and alertness |
| Recovery | Continuous | 20–30 min | P3–P4 | Circulation and tissue support |
| Skin Health | Continuous | 15–20 min | P2–P3 | Anti-inflammatory and dermal benefits |
| Sleep Support | 10 Hz (evening) | 15–20 min | P2 | Use 60–90 min before bedtime |
| Pain Relief | Continuous | 20–30 min | P3–P4 | Deep-tissue comfort and recovery |
| Goal | Mode | Time | Intensity | Frequency | Intended Outcome |
|---|---|---|---|---|---|
| Stress / Anxiety | 10 Hz | 20–25 min | P2–P3 | 3–4×/week | Autonomic downregulation |
| Sleep Optimization | 10 Hz | 15–20 min | P2 | Evening | Pre-sleep relaxation |
| Cognitive Performance | 40 Hz | 10–20 min | P2–P3 | Morning | Cognitive activation |
| Pain / Muscle Recovery | Continuous | 20–30 min | P3–P4 | As needed | Soreness and tissue support |
| Skin Health | Continuous | 15–20 min | P2–P3 | 3×/week | Collagen support and inflammation reduction |
| Athletic Performance Recovery | Continuous + 10 Hz | 20–25 min | P3–P4 | Post-workout | Enhanced recovery and readiness |
| Phase | Days | Mode(s) | Time | Intensity | Purpose |
|---|---|---|---|---|---|
| Phase 1: Adaptation | Days 1–7 | Continuous + 10 Hz | 15–20 min | P2 | Initial acclimation |
| Phase 2: Stabilization | Days 8–14 | Continuous + 10 Hz + optional 40 Hz | 20 min | P2 → P3 | Increased therapeutic engagement |
| Phase 3: Engagement | Days 15–21 | All modes | 20–25 min | P3 | Full therapeutic participation |
| Phase 4: Optimization | Days 22–30 | User preference | 25–30 min | P3 → P4 | Peak benefit phase |

Power off and unplug the device once treatment is complete.
Allow the pod to cool before folding, transporting, or storing.
Cleaning:
Wipe interior and exterior surfaces with a soft cloth and a mild, non-toxic cleanser.
Do not use abrasive tools, solvents, or alcohol-based products.
Storage:
Store flat or loosely rolled—avoid sharp folds or creasing of LED panels.
Do not stack heavy objects on top of the device.
Keep away from moisture; never submerge or expose to water.
The device is intended for home use only and is not approved for use in commercial or clinical facilities.
Do not use if contraindications apply, including pregnancy, epilepsy, metal implants, active dermatologic conditions, or any restriction noted in the user manual.
Do not attempt self-repair, disassembly, or modification—service must be performed exclusively by Capillus.
Warranty: 1-year limited warranty covering manufacturing defects.
Inspect the pod, power supply, and controller before each session. Discontinue use if any damage is observed.
Ensure all cables are firmly connected
Confirm that the electrical outlet is functioning
Recheck controller-to-device connection
Power cycle the unit
Mild warmth is expected during use
Reduce intensity or stop the session if discomfort occurs
For service, warranty inquiries, or technical assistance, contact Capillus customer support